Functional features 1 high-voltage DC power on the battery can be converted into low-voltage DC 12V 2. DC-DC 12V backup battery can be charged on the management 3 display the working status, fault codes and other DC-DC panel lights by 4 waterproof seal forms, no fan, convection cooled Protection 1 Input undervoltage protection 2 output over-voltage protection 3 output overcurrent limit 4 Output short circuit protection 5. Input reverse polarity protection 6. Temperature protection DC-DC voltage of the input current (voltage range of 280V-380V) Input Voltage Input Current 280V ≤ 4A 320V ≤ 3.5A 380V ≤ 3A Output Specifications Item Rating error range The maximum DC output voltage 13.6V ± 0.1V The maximum DC output current 70A ± 1A The maximum DC output power 1000W / Efficiency ≥ 89% / Application Environment Project Description Application Environment Ambient temperature -30 ~ 60 ℃ / Storage temperature -45 ~ 90 ℃ / Relative humidity 5% to 95% non-condensing Protection class Standard Grade GB4208-2008IP66 The electric shock Electric shock on the current value ≤ 5A Withstand voltage performance Terminals on the ground (shell) and dielectric strength of each radio link between circuits should be able to withstand the test voltage in the table below, the test voltage to AC voltage of 50 to 60, between test terminals should not appear corona, ionized, arcing or breakdown. Enter the shell 1500V AC1min leakage current ≤ 10mA Input to output leakage current ≤ 10mA 1500V AC1min The output of the shell leakage current ≤ 10mA 500V AC1min Insulation Resistance DC-DC insulation resistance live circuit and ground (case) between the ambient temperature (23 ± 2) ℃ and relative humidity of 80% to 90%, not less than 20M. Contact current Contact current DC current category Limit ≤ 2mA Noise Noise conditions ≤ 55dB distance 1.5m, A-weighted Grounding resistance should be less than 0.1Ω. Grounding conductor must use the yellow / green and white color line Electromagnetic compatibility DC-DC electromagnetic compatibility to meet the GB / T 18487.3-2001 in 11.3 electromagnetic environment testing requirements Wiring bundle requirements Project core protection requirements DC input sets of 2.5m square orange bellows DC output 16m square sleeve black bellows 12V enable line 0.75m square sleeve orange bellows Reliability Index data definition description MTBF150000H reliability introduced by device failure rate |