Air-conditioning control assy
Power window switch
Volume control switch series
Combination switch series
Steering wheel combination switch series
Door light control switch
Instrument panel switch series
Instrument of small switch series
Fog lamp switch series
Electric rearview mirror switch series
Defrost switch series
Trunk switch series
Dimmer switch series
Alarm switch series
Console switch series
Other switch series
CD panel series
Vehicle power series
Vehicle power series You are in: Home > Products > Vehicle power series
DC-DC Series
 
 
Product description:

 

Product Description:

Functional features
1 high-voltage DC power on the battery can be converted into low-voltage DC 12V 
2. DC-DC 12V backup battery can be charged on the management 
3 display the working status, fault codes and other DC-DC panel lights by 
4 waterproof seal forms, no fan, convection cooled 
 
Protection 
1 Input undervoltage protection 
2 output over-voltage protection 
3 output overcurrent limit 
4 Output short circuit protection 
5. Input reverse polarity protection 
6. Temperature protection 
 
DC-DC voltage of the input current (voltage range of 280V-380V) 
Input Voltage Input Current 
280V 4A 
320V 3.5A 
380V 3A 

 
Output Specifications 
Item Rating error range 
The maximum DC output voltage 13.6V ± 0.1V 
The maximum DC output current 70A ± 1A 
The maximum DC output power 1000W / 
Efficiency 89% / 

 
Application Environment 
Project Description Application Environment 
Ambient temperature -30 ~ 60 / 
Storage temperature -45 ~ 90 / 
Relative humidity 5% to 95% non-condensing 

 
Protection class 
Standard Grade 
GB4208-2008IP66 

 
The electric shock 
Electric shock on the current value 5A 
 
Withstand voltage performance 
Terminals on the ground (shell) and dielectric strength of each radio link between circuits should be able to withstand the test voltage in the table below, the test voltage to AC voltage of 50 to 60, between test terminals should not appear corona, ionized, arcing or breakdown. 
 
Enter the shell 1500V AC1min leakage current 10mA 
Input to output leakage current 10mA 1500V AC1min 
The output of the shell leakage current 10mA 500V AC1min 

 
Insulation Resistance 
DC-DC insulation resistance live circuit and ground (case) between the ambient temperature (23 ± 2) and relative humidity of 80% to 90%, not less than 20M. 
 
Contact current 
Contact current DC current category 
Limit 2mA 

 
Noise 
Noise conditions 
55dB distance 1.5m, A-weighted 

 
Grounding resistance should be less than 0.1Ω. 
 
Grounding conductor must use the yellow / green and white color line 
 
Electromagnetic compatibility 
DC-DC electromagnetic compatibility to meet the GB / T 18487.3-2001 in 11.3 electromagnetic environment testing requirements 
 
Wiring bundle requirements 
Project core protection requirements 
DC input sets of 2.5m square orange bellows 
DC output 16m square sleeve black bellows 
12V enable line 0.75m square sleeve orange bellows 

 
Reliability 
Index data definition description 
MTBF150000H reliability introduced by device failure rate


 
[Top] [Back]